- CLIENTUber Boat by Thames Clippers
- PROJECTMonsoon Emergency Repair 2025
- PROCEDURE REFERENCEMWI-PRO-001
- TEST LOCATIONTilbury Docks
- NDT INSPECTORMartin Brettell
- CSWIP/PCN LEVELCSWIP Level 2 - 640535
- REPORT NOMWI-REP-1157
- REPORT DATE25/08/2025
- NDT DRAWING NO-
- TEST DATE24/08/2025
- NDT ZONEStarboard Bow Repair
EQUIPMENT SPECIFICATION AND EXAMINATION REQUIREMENTS
ACCEPTANCE CRITERIA
TESTING STANDARD
DNV Rules for classification of ships, Part 2, Chapter 2, Section 8, Table 10
BS EN ISO 3452-1: 2013
EQUIPMENT
MANUFACTURER
DESCRIPTION
SERIAL NO.
Liquid Penetrant SKL-SP2
Magnaflux
SKL - SP2
160904
Cleaner SKC-S
Magnaflux
SKS-S
160911
Developer SKD-S2
Magnaflux
SKD-S
161002
LED Inspection Light
Nebo
N/A
MWI_EQP_244
| MATERIAL SPECIFICATION AND TESTING CONDITIONS | |
|---|---|
| MATERIAL TESTED | Aluminium |
| SURFACE CONDITION | Smooth, as welded |
| MATERIAL TEMPERATURE | Ambient |
| VIEWING CONDITION/LIGHT SOURCE | Natural light and LED torch |
| MATERIAL THICKNESS (MM) | 6mm |
| TEST RESTRICTIONS | None |
| WELDING PROCESS | GMAW - Pulse |
| POST WELD HEAT TREATMENT | None |
Starboard Bow Repair