- CLIENTUber Boat by Thames Clippers
- PROJECTTyphoon P-Bracket Repair
- PROCEDURE REFERENCEMWI-PRO-001
- TEST LOCATIONTilbury Docks
- NDT INSPECTORMartin Brettell
- CSWIP/PCN LEVELCSWIP Level 2 - 640535
- REPORT NOMWI-REP-1168
- REPORT DATE07/10/2025
- NDT DRAWING NO-
- TEST DATE30/09/2025
- NDT ZONEPort & Starboard hull plating around P-Bracket
EQUIPMENT SPECIFICATION AND EXAMINATION REQUIREMENTS
ACCEPTANCE CRITERIA
TESTING STANDARD
DNV Rules for classification of ships, Part 2, Chapter 2, Section 8, Table 10
BS EN ISO 3452-1: 2013
EQUIPMENT
MANUFACTURER
DESCRIPTION
SERIAL NO.
Liquid Penetrant SKL-SP2
Magnaflux
SKL - SP2
160904
Cleaner SKC-S
Magnaflux
SKS-S
160911
Developer SKD-S2
Magnaflux
SKD-S
161002
LED Inspection Light
NEBO
N/A
MWI_EQP_244
| MATERIAL SPECIFICATION AND TESTING CONDITIONS | |
|---|---|
| MATERIAL TESTED | Aluminium |
| SURFACE CONDITION | Smooth, as welded |
| MATERIAL TEMPERATURE | Ambient |
| VIEWING CONDITION/LIGHT SOURCE | Natural light and LED torch |
| MATERIAL THICKNESS (MM) | 5mm, 6mm, 8mm and 10mm |
| TEST RESTRICTIONS | None |
| WELDING PROCESS | GMAW - Pulse |
| POST WELD HEAT TREATMENT | None |
Dye Penetrant Inspection